Do you have some public code you could link to that you’re having this issue with? There isn’t a one-size-fits-all solution for Rc/RefCell, I think.
Do you have some public code you could link to that you’re having this issue with? There isn’t a one-size-fits-all solution for Rc/RefCell, I think.
Whoa nice, I need to keep this in mind.
Interesting. I can’t find anything about the FLAC licensing issues. Do you have a link?
(Also, correction — Wikipedia says macOS in general can play FLAC. I guess it’s just the Music app that can’t import them.)
Yep. Lack of format support is usually to blame on the one who doesn’t support the format. You can absolutely blame Apple for this too though, their apps can’t open e.g. Matroska video or FLAC.
And perplexingly, they don’t support uploading HEIC, their own image format of choice, on the web iCloud Photos. So there’s that too.
(At this point my music library is stored as ALAC because it’s well supported in both Linux and Apple’s OSes. Really wish it wouldn’t have to be that way though. Someone needs to tell them about ffmpeg.)
For example they used to have their own video container .mov
It’s always very very funny every time someone mentions MOV, because while it’s very similar to MP4, it’s actually an open format while MP4 isn’t (!). You actually have to pay for the MP4 standard document while Apple just gives you the MOV documentation.
Also at least taking a screen capture on macOS still gives you a MOV container, actually.
The article starts with a table of contents with the change highlights as the first item.
The proton prefix should not be created on the external drive, but in the Steam folder in the home directory, I’m pretty sure. Even with a second Steam game install location. Why is it not there?
I’m guessing proton is trying to create this symlink when it installs .NET
No, it is created when Wine initializes the prefix. It has absolutely nothing to do with .NET.
It’s not “c”, it’s “c:”
dosdevices/c: is missing I’m assuming is what you mean? That’s very weird, it is there in every wine prefix and should be a link to …/drive_c.
Proton is on a different drive than BG3, could that cause issues?
I don’t think so.
Try deleting the prefix (steamapps/compatdata/1086940). This should work completely fine out of the box. (Not sure if uninstalling the game deletes that already, just in case)
Now that I think about it, dovecot drops permissions for security reasons (login runs as the “dovenull” user). It’s probably not a good idea to try to circumvent that actually.
What do you mean by “more powerful” wrt CMake?
CMake is a turing-complete language with some APIs that Meson either doesn’t have an equivalent yet because it’s comparatively new (for example, until 2023, there was no built in way to get a relative path from two paths, and if you wanted that you had to shell out to an external program), or they aren’t going to add because it doesn’t fit their design.
Meson is (intentionally) limited in terms of extensibility, instead it tries to come with everything built in that you need, even down to specific library support like Qt, from what it seems like to me. For example, you cannot define your own functions, it ships builtin modules but does not allow other packages to provide their own (for example like KDE’s Extra CMake Modules), to name a few that I’m familiar with and why I was put off using it so far.
I have yet to see how actually limiting that is, going to try to move the project I’ve been working on for years that relies on some of these CMake features to Meson soon and see how it fares. But considering that big projects like GNOME use it all over the place it’s probably workable in practice, I’ll just have to rethink the existing approach a bit.
Is that considered bait?
Wasn’t it? Go’s build system is very much not what I would call an example of good design (exhibit A: load-bearing comments and file names).
I meant that for my one IP address, I set it to have a PTR to multiple domain names.
Don’t do that, yeah. If set it should always point to one domain name, the canonical name for that host, and the domain name should resolve back to that IP.
See https://serverfault.com/questions/618700/why-multiple-ptr-records-in-dns-is-not-recommended
Try Meson first, it should support compiling GNU assembly via the C compiler from what I can find. I’ve been using CMake for years because it is more powerful (finally trying out Meson though for a new project) but in contrary to Meson it is easy to use the wrong way if you don’t know what you’re doing. Meson is very clean in comparison, and also very easy to get started with. (And both these are absolutely better than autotools)
(If only c++ build systems caught up to Golang lol)
Terrible bait
Try this I suppose
userdb {
args = username_format=%n /etc/passwd
driver = passwd-file
}
And maybe similar with passdb and /etc/shadow?
What do you have your passdb set to if you don’t mind me asking?
The defaults. Doesn’t show up in doveconf -n.
Currently I have multiple PTR records for all the subdomains I’m using, which hasn’t caused problems yet…
Wait, what? PTR is set on an IP address, not on a domain name. It should resolve to the canonical domain name of the host behind that IP.
Your postfix is set to deliver to lmtp:unix:private/dovecot-lmtp so you need to create the socket there:
service lmtp {
- unix_listener lmtp {
+ unix_listener /var/spool/postfix/private/dovecot-lmtp {
group = postfix
mode = 0600
user = postfix
}
}
(though for me the path is /var/lib/postfix/queue/private/dovecot-lmtp. YMMV)
What would you suggest I set the PTR record to?
Set system hostname, PTR, and myhostname to NAME.domain.com where NAME is a unique name that you made up (e.g. I have ‘polaris.dblsaiko.net’). This also makes adding more hosts later less awkward (as opposed to having the hostname be domain.com).
For the IMAP login issue, I’m pretty sure this is the cause looking at the “unknown user” error:
userdb {
args = username_format=%u /etc/dovecot/users
driver = passwd-file
}
Have you set up the users in that file (/etc/dovecot/users) if you even want to do that instead of just using passwd? Also note %u is the full user string including domain. Not sure how that plays together with auth_username_format=%n which is just the user name.
Personally I just have
userdb {
driver = passwd
}
so I don’t have anything further to go off of.
Okay, there are two different issues here. First, the mail delivery.
You have
mydomain = domain.com
myhostname = mail.domain.com
and getting
Relay access denied (in reply to RCPT TO command)
This means that received mail is addressed to a domain that is not configured for local delivery, and the mail server is not accepting it to be relayed to the actual target server. This is a good thing, you do not want to have a public relay under any circumstances because it would mean people could make your server launch spam anywhere.
As for why it’s not configured to accept that domain for local delivery, you need to look at the mydestination setting:
mydestination (default: $myhostname, localhost.$mydomain, localhost)
The list of domains that are delivered via the $local_transport mail delivery transport. […]
(from postconf(5).)
You left it at the default value, so it will accept mail addressed to mail.domain.com, localhost.domain.com, and localhost. You’ll probably want to set that to additionally contain $mydomain (at least that is how mine is configured).
Also, something else:
My server’s hostname is domain.com not mail.domain.com (mail.domain.com is what my MX record points to), but this shouldn’t really matter as I configured postfix with:
You’ll want those to match up, system hostname and postfix’s myhostname, since you’ll need to set the PTR record of your IP to match the hostname your SMTP server identifies itself as, and otherwise your server’s IP resolves to mail.domain.com while the canonical hostname is domain.com. It will work for mail, it’ll just not be nice when your server’s IP resolves to mail.domain.com for stuff that isn’t mail and that isn’t the canonical hostname. I recommend giving it some other hostname (or just setting both to mail.domain.com if the system just handles mail).
Not for the built-in Eq derive macro. But you can write your own derive macros that do allow you to take options, yeah.